Specifications

Pump Type Double plunger reciprocating pump (Binary high-pressure gradient pump, 2 sets)
Flow Range 0.001 mL/min to 10.000 mL/min
Setting Step Size 0.001 mL/min
Flow Accuracy ≤ ± 0.3 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Stability RSD ≤ 0.1 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Maximum Pressure 42 MPa
Display Pressure Error ≤ ± 3.0 %
Pressure Fluctuation ≤ 1.0 %
Wavelength Range 190 nm to 700 nm
Wavelength Repeatability ± 0.1 nm
Wavelength Accuracy ≤ ± 1.0 nm
Spectrum Band Width 8 nm
Response Time 0.0 sec to 4.9 sec
Linearity Range 1.8 AU (5 %)
Baseline Noise ≤ ± 1×10^-5 AU
Baseline Drift ≤ 2.0 × 10^-4 AU/h
Minimum Detectable Concentration 4.0×10^-9 g/mL (Naphthalene in Methanol Solution)
Detector Cell Path Length 10 mm
Detector Cell Volume 10 μL
Light Source Deuterium Lamp
Power Dissipation (Pump) 80 W
Power Dissipation (Detector) 100 W
Power Supply AC 110 V / 220 V ± 10 %, 50 Hz / 60 Hz

Features

  • VFD screen for process control
  • Deuterium light source
  • Optical path detector cell of volume 10µL
  • One set double plunger reciprocating pump

Standard Accessories

Accessory No Accessory
1) Sample injector
2) HPLC column ( 5 µm, ID 6 × 200 mm )
3) Work station
4) Value mounting frame
5) Gradient system kit

Applications

Used to split a mixture of compounds in the fields of analytical chemistry, biochemistry and industrial.
High Performance Liquid Chromatography LB-11HPLC Banner
High Performance Liquid Chromatography LB-11HPLC Banner

Get Quote

Frequently asked questions For

1. What is an HPLC system used for?

Our HPLC systems are used to separate and analyze mixtures of substances. They are commonly used in pharmaceutical laboratories, food safety testing, medical diagnostics, and research institutions.

2. Does Labotronics offer HPLC systems for routine laboratory testing?

Yes, Labotronics offers HPLC systems that are suitable for both routine testing and more advanced applications. They are designed to deliver consistent and accurate results.

3. What makes Labotronics HPLC systems reliable?

Our systems are built with high-quality pumps and advanced flow control features to ensure stability and performance throughout testing.

4. What are the main applications of Labotronics HPLC?

Labotronics HPLC systems are ideal for analyzing pharmaceuticals, food products, environmental samples, and chemical formulations.

5. Can I use this for academic or research purposes?

Absolutely. Many academic institutions and research laboratories use Labotronics HPLC systems for experimental analysis and teaching purposes.

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

High Performance Liquid Chromatography (HPLC)

Flow Range 0.001 to 10.000 mL/min
Flow Rate Increment 0.001 mL
Flow Accuracy ≤ ± 0.2% (1.00 mL/min, H₂O, R.T., 8.5 MPa)
Flow Stability RSD ≤ 0.06% (1.00 mL/min, H₂O, R.T., 8.5 MPa)
Flow Range 0.001 to 10.000 mL/min (step: 0.001 mL/min)
Temperature Range 0 to 40°C
Flow Accuracy ± 0.2% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature)
Flow Precision RSD ≤ 0.075% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature)
Pump Type Isocratic Pump (1 Set)
Flow Rate Range 0.001 mL/min to 10.000 mL/min
Flow Accuracy ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Precision RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Range 0.001 to 10.000 mL/min
Flow Rate Increment 0.001 mL/min
Flow Accuracy ≤ ± 0.3% (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Stability RSD ≤ 0.1% (1.00 mL/min, H2O, R.T., 8.5 MPa)
Pump Type Quaternary low-pressure pump
Flow Rate Range 0.001 to 10.000 mL/min, in 0.001 mL increments
Flow Accuracy ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Precision RSD ≤ 0.06 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Pump Type Quaternary low-pressure gradient pump (1 Set)
Flow Rate Range 0.001 mL/min to 10.000 mL/min
Flow Accuracy ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Flow Precision RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa)
Pump Type Low-Pressure Quaternary Constant Flow Pump
Pump Flow Rate 0.001 to 10.000 mL/min (step 0.001 mL/min)
Gradient Accuracy ≤ ±1%
Retention Time Repeatability ≤ 0.1%
×