UV-Visible Spectrophotometer LB-21UVS is a light intensity measuring unit with wavelength range 195 nm ~ 1020 nm. Achromatic Czerny-Turner optical system and LED display for accurate analysis of samples.It is equipped with tungsten and deuterium lamp as a light source with manual wavelength setting providing flexibility in the positioning of reflector mirror.
Get Quote Download CatalogSpecifications
| Optical system | Achromatic Czerny-Turner (1200 L/mm grating) |
| Wavelength range | 195 nm ~ 1020 nm |
| Spectral bandwidth | 5 nm |
| Wavelength accuracy | ± 2 nm |
| Wavelength repeatability | 1 nm |
| Wavelength setting | Manual |
| Display | LED |
| Detector | Silicon photodiode |
| Stray light | ≤ 0.3 % T |
| Photometric accuracy | 0.5 % T |
| Photometric repeatability | 0.2 % T |
| Photometric range | 0 to 200 % T -0.301 to 2.000 A |
| Drift | ≤ 0.2 % T |
| Noise | 100 % ≤ 0.3 % T |
| Display range | 0 to 200 % T -0.3 to 2 A |
| Light switch mode | Manual |
| Stability | ± 0.004 A/h at 500 nm |
| Light source | Tungsten and Deuterium |
| Measurement modes | T,A,C |
| Power | AC 110 V,50 Hz AC 220 V,60 Hz |
| Dimensions ( L x W x H ) | 520 x 450 x 300 mm |
| Weight | 12 kgs |
Features
Applications
Used in biochemistry, clinical and research labs, life sciences petrochemical, quality, control agriculture, environmental protection for concentration measurement, sample analysis, impurities detection, chemical kinetics, etc.| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 320 nm ~ 1020 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | 0.2 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 325 nm ~ 1000 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 200 nm ~ 1020 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Optical system | Achromatic Czerny-Turner (1200 L/mm grating) |
| Wavelength range | 190 nm ~ 1100 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 190 nm ~ 1100 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 0.5 nm |
| Wavelength Range | 190 to 1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | 0.5 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 190 nm ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ± 0.5 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 320 nm ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ± 0.5 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 320 nm ~ 1100 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 0.5 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 320 nm ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ± 0.5 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 200 nm ~ 1020 nm |
| Spectral bandwidth | 4 nm |
| Wavelength accuracy | ± 2 nm |
| Optical system | Single beam (1200 lines/mm grating) |
| Wavelength range | 190 nm ~ 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength accuracy | ± 0.5 nm |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.eu
WhatsApp: +1 579 401 0534