Get Quote Download CatalogSpecifications
| Elements detected | K, Na, Li, Ca |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Li- 0.1 ppm Ca- 2 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Li- 0 ppm ~ 100 ppm Ca- 0 ppm ~ 1000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Li- ≤0.105 ppm Ca- ≤2 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm ) Li- 0.15 ppm (0.25 ppm ~ 5 ppm) Ca- 3 ppm (5 ppm ~ 100 ppm) |
| Linearity error | K- ≤0.195 ppm Na- ≤0.69 ppm Li- ≤0.147 ppm Ca- ≤3 ppm |
| Sample uptake | < 6 mL/min |
| Repeatability | 1% CV for 20 consecutive samples |
| Response time | < 8s |
| Ambient temperature | 10 °C ~ 35 °C |
| Humidity | ≤ 85% |
| Power supply | AC 110 V ±10%; 50 Hz AC 220 V ±10%; 60 Hz |
| Power consumption | 250 W |
| Dimensions | 580 × 540 × 400 mm |
| Weight | 18 kgs |
Features
Standard Accessories
| Sr. No. | Name of the accessory | Quantity |
|---|---|---|
| 1. | Air compressor | 1 unit |
Applications
Used in the fields agriculture, chemistry, pharmacology, pathology, biology, forensics, etc. for analysis of particular elements in the material.| Elements detected | K, Na, Ba |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Ba- 6 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Ba- 0 ppm ~ 3000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Ba- ≤60.28 ppm |
| Elements detected | K, Na, Li |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Li- 0.01 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Li- 0 ppm ~ 100 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Li- 0.105 ppm |
| Elements detected | K, Na, Ca |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Ca- 2 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Ca- 0 ppm ~ 1000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Ca- ≤2 ppm |
| Measurement Range | Potassium (K): 0 to 100 ppm Sodium (Na): 0 to 160 ppm |
| Minimum Detection Limit | Potassium (K): 0.1 ppm Sodium (Na): 0.1 ppm |
| Linear Error | Potassium (K): ± 0.2 ppm Sodium (Na): ± 0.5 ppm |
| Display Range | Potassium (K): 0 to 100 μg/ml Sodium (Na): 0 to 160 μg/ml |
| Elements detected | K, Na |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm |
| Measuring range | K: 0.195 ppm (0.39 to 3.12) ppm Na: 0.69 ppm (1.15 to 9.2) ppm Li: 0.15 ppm (0.25 to 5) ppm Ca: 3 ppm (5 to 100) ppm Ba: 9 ppm |
| Sensitivity | K: 0.01 ppm Na:0.01 ppm Li: 0.1 ppm Ca: 2 ppm Ba: 6 ppm |
| Repeatability | 1% CV for 20 consecutive samples |
| Sample uptake | < 6 ml/min |